光(guang)(guang)(guang)(guang)(guang)電(dian)(dian)池(chi)是(shi)把光(guang)(guang)(guang)(guang)(guang)能直接(jie)轉換成電(dian)(dian)能的光(guang)(guang)(guang)(guang)(guang)電(dian)(dian)元(yuan)件。當光(guang)(guang)(guang)(guang)(guang)線(xian)射(she)到硒(xi)(xi)光(guang)(guang)(guang)(guang)(guang)電(dian)(dian)池(chi)表(biao)面(mian)(mian)時,入(ru)射(she)光(guang)(guang)(guang)(guang)(guang)透(tou)過金屬(shu)薄膜4到達半導體硒(xi)(xi)層2和金屬(shu)薄膜4的分界(jie)面(mian)(mian)上(shang),在界(jie)面(mian)(mian)上(shang)產生(sheng)光(guang)(guang)(guang)(guang)(guang)電(dian)(dian)效應。產生(sheng)的光(guang)(guang)(guang)(guang)(guang)生(sheng)電(dian)(dian)流(liu)的大小與光(guang)(guang)(guang)(guang)(guang)電(dian)(dian)池(chi)受光(guang)(guang)(guang)(guang)(guang)表(biao)面(mian)(mian)上(shang)的照(zhao)(zhao)度(du)(du)有一(yi)定(ding)的比例關系。這時如果(guo)接(jie)上(shang)外電(dian)(dian)路,就會有電(dian)(dian)流(liu)通過,電(dian)(dian)流(liu)值從以(yi)勒(le)克斯(Lx)為刻度(du)(du)的微(wei)安表(biao)上(shang)指示出來(lai)。光(guang)(guang)(guang)(guang)(guang)電(dian)(dian)流(liu)的大小取決于入(ru)射(she)光(guang)(guang)(guang)(guang)(guang)的強弱(ruo)。照(zhao)(zhao)度(du)(du)計有變檔裝置,因此(ci)可(ke)以(yi)測(ce)高(gao)照(zhao)(zhao)度(du)(du),也(ye)可(ke)以(yi)測(ce)低照(zhao)(zhao)度(du)(du)。引照(zhao)(zhao)度(du)(du)計的種類:1.目視照(zhao)(zhao)度(du)(du)計:使用不便,精度(du)(du)不高(gao),很少(shao)使用2.光(guang)(guang)(guang)(guang)(guang)電(dian)(dian)照(zhao)(zhao)度(du)(du)計:常用硒(xi)(xi)光(guang)(guang)(guang)(guang)(guang)電(dian)(dian)池(chi)照(zhao)(zhao)度(du)(du)計和硅光(guang)(guang)(guang)(guang)(guang)電(dian)(dian)池(chi)照(zhao)(zhao)度(du)(du)計。
1.目視照度計:使用不便,精度不高(gao),很少使用
2.光電(dian)照(zhao)(zhao)度(du)計:常(chang)用硒光電(dian)池照(zhao)(zhao)度(du)計和硅光電(dian)池照(zhao)(zhao)度(du)計
光(guang)電池(chi)照度計(ji)的組成與使用要求:
1.組成:微安表、換擋旋紐、零點(dian)調(diao)節、接線柱、光(guang)電池、V(λ)修正濾(lv)光(guang)器(qi)等組成。
常(chang)用(yong)硒(Se)光(guang)電(dian)池(chi)或硅(gui)(Si)光(guang)電(dian)池(chi)照度計,又稱勒克斯表。
2.使用(yong)要(yao)求:照度計(ji)探頭(tou)是玻璃材質(zhi),容易摔(shuai)壞破(po)損,同(tong)時(shi)使用(yong)時(shi)防水效果很差。
①光電池(chi)應用(yong)直(zhi)線性(xing)好的硒(Se)光電池(chi)或硅(Si)光電池(chi);長時(shi)間工作仍能保(bao)持良好的穩(wen)定性(xing),且靈(ling)敏度高(gao);高(gao)E時(shi)選用(yong)高(gao)內阻的光電池(chi),其靈(ling)敏度低而線性(xing)好,受(shou)強(qiang)光照射(she)不易受(shou)損
②內付(fu)有V(λ)修正濾光片(pian),適宜用(yong)異色溫光源的照度,誤差小
③光電池(chi)前加一塊余(yu)弦角(jiao)度補(bu)償器(乳白玻璃或白色(se)塑料)原因(yin)是入射角(jiao)大時,光電池(chi)偏離余(yu)弦定則
④照度(du)(du)計(ji)應工作在室溫或接近室溫下(xia)(光(guang)電池漂移隨(sui)溫度(du)(du)改(gai)變(bian)而發生改(gai)變(bian))
①打開電源。
②打開(kai)光(guang)(guang)檢測器(qi)蓋子(zi),并(bing)將光(guang)(guang)檢測器(qi)水(shui)平放在測量位置。
③選(xuan)擇(ze)適合(he)測(ce)量檔位。
如(ru)果(guo)顯示(shi)屏(ping)左端只顯示(shi)“1”,表示(shi)照度過量(liang),需要按下量(liang)程(cheng)鍵(⑧鍵),調整測量(liang)倍數。
④照度計開始工作(zuo),并在顯(xian)示(shi)屏(ping)上顯(xian)示(shi)照度值。
⑤顯示(shi)屏上顯示(shi)數(shu)據(ju)不斷(duan)地變動,當顯示(shi)數(shu)據(ju)比較穩定時(shi),按下HOLD鍵,鎖定數(shu)據(ju)。
⑥讀取并記錄讀數(shu)器中顯示的觀(guan)測(ce)值。觀(guan)測(ce)值等于讀數(shu)器中顯示數(shu)字與(yu)量(liang)程(cheng)值的乘積。
比如:屏幕(mu)上顯(xian)示(shi)500,右下角(jiao)顯(xian)示(shi)狀(zhuang)態為“×2000”,照(zhao)度測(ce)量值(zhi)為1000000lx,即(500×2000)。
⑦再按一下鎖定開關,取消讀值鎖定功能。
⑧每一(yi)次觀測時,連續讀數(shu)三次并記(ji)錄。
⑨每一次(ci)測量工作(zuo)完成后,按下(xia)電源開關鍵,切斷電源。
⑩蓋上光檢測器蓋子(zi),并放回盒里。
使Ls垂(chui)直照射光(guang)電池→E=I/r2,改(gai)變r可得不同(tong)照度下的(de)光(guang)電流(liu)值,由E與i的(de)對應關系(xi)將電流(liu)刻度轉換(huan)為照度刻度。
利用光(guang)強標準(zhun)燈,在近似點光(guang)源(yuan)的(de)工作距離下(xia),改變(bian)光(guang)電池與(yu)標準(zhun)燈的(de)距離l,記錄(lu)下(xia)各個距離下(xia)的(de)電流(liu)(liu)計的(de)讀數,由距離平方反比定律E=I/r2計算光(guang)照(zhao)度(du)(du)E,由此可(ke)以得到一(yi)系列不同(tong)照(zhao)度(du)(du)的(de)光(guang)電流(liu)(liu)值i,作光(guang)電流(liu)(liu)i與(yu)照(zhao)度(du)(du)E的(de)變(bian)化曲(qu)線(xian),即為(wei)照(zhao)度(du)(du)計的(de)定標曲(qu)線(xian)由此可(ke)對照(zhao)度(du)(du)計表盤(pan)進行分度(du)(du)即為(wei)照(zhao)度(du)(du)計的(de)定標
光(guang)電池和電流計(ji)更換時需重新定(ding)(ding)標(biao)(biao);照度(du)(du)計(ji)使用一段時間后應(ying)對照度(du)(du)計(ji)重新進行(xing)定(ding)(ding)標(biao)(biao)(一般一年內應(ying)檢定(ding)(ding)1-2次(ci));高精度(du)(du)的(de)照度(du)(du)計(ji)可(ke)用光(guang)強標(biao)(biao)準(zhun)燈進行(xing)檢定(ding)(ding);擴大(da)照度(du)(du)計(ji)的(de)定(ding)(ding)標(biao)(biao)量程可(ke)改(gai)變(bian)距離r,也可(ke)選用不同的(de)標(biao)(biao)準(zhun)燈,選用小量程的(de)電流計(ji)
照(zhao)(zhao)度與人(ren)們的(de)(de)(de)(de)(de)(de)生活有(you)著密切的(de)(de)(de)(de)(de)(de)關(guan)系。充足的(de)(de)(de)(de)(de)(de)光(guang)(guang)照(zhao)(zhao),可(ke)防止人(ren)們免(mian)遭意外事(shi)故的(de)(de)(de)(de)(de)(de)發生。反(fan)之,過(guo)暗的(de)(de)(de)(de)(de)(de)光(guang)(guang)線(xian)可(ke)引起人(ren)體(ti)疲勞的(de)(de)(de)(de)(de)(de)程度遠(yuan)(yuan)遠(yuan)(yuan)超過(guo)眼睛(jing)的(de)(de)(de)(de)(de)(de)本(ben)身。因(yin)此,不(bu)適或(huo)較(jiao)差的(de)(de)(de)(de)(de)(de)照(zhao)(zhao)明(ming)條件是造成(cheng)事(shi)故和疲勞的(de)(de)(de)(de)(de)(de)主要原因(yin)之一。現有(you)統計資料(liao)表明(ming),在所有(you)職業(ye)勞動的(de)(de)(de)(de)(de)(de)事(shi)故中約有(you)30%是直接(jie)或(huo)間(jian)接(jie)因(yin)光(guang)(guang)線(xian)不(bu)足所造成(cheng)的(de)(de)(de)(de)(de)(de)。對體(ti)育(yu)場(館)的(de)(de)(de)(de)(de)(de)光(guang)(guang)照(zhao)(zhao)要求是非(fei)常嚴格(ge)的(de)(de)(de)(de)(de)(de),光(guang)(guang)照(zhao)(zhao)過(guo)強或(huo)過(guo)暗都會影響比賽的(de)(de)(de)(de)(de)(de)效果。
那么,人們(men)居住的(de)(de)(de)室內對(dui)照(zhao)(zhao)度(du)的(de)(de)(de)衛(wei)生學要求(qiu)是(shi)如何呢?照(zhao)(zhao)度(du)是(shi)在(zai)衛(wei)生學中一(yi)項十分重要的(de)(de)(de)指(zhi)標。光(guang)是(shi)指(zhi)能引(yin)起人眼(yan)睛光(guang)亮感覺(jue)的(de)(de)(de)電(dian)磁輻(fu)射,當光(guang)線進入(ru)眼(yan)睛后可產生的(de)(de)(de)知(zhi)覺(jue)稱為視覺(jue)。人們(men)所見(jian)的(de)(de)(de)光(guang)是(shi)指(zhi)可見(jian)光(guang),其(qi)波長(chang)范圍在(zai)380~760nm(納米)之間。
采光(guang)(guang)可分為(wei)自(zi)(zi)然(ran)采光(guang)(guang)和(he)(he)人工光(guang)(guang)源兩大類。自(zi)(zi)然(ran)采光(guang)(guang)是指(zhi)室內(nei)和(he)(he)地區的(de)(de)天然(ran)照(zhao)度,有(you)直接的(de)(de)日光(guang)(guang)照(zhao)散(san)射光(guang)(guang)和(he)(he)周(zhou)圍物(wu)體的(de)(de)反(fan)(fan)射光(guang)(guang),常用采光(guang)(guang)系(xi)(xi)數和(he)(he)自(zi)(zi)然(ran)照(zhao)度表示。而(er)采光(guang)(guang)系(xi)(xi)數是指(zhi)采光(guang)(guang)口的(de)(de)有(you)效面積(ji)與室內(nei)地面面積(ji)之(zhi)比。一般住宅的(de)(de)采光(guang)(guang)系(xi)(xi)數在1/5~1/15之(zhi)間,居住面積(ji)比在1/8~1/10之(zhi)間(窗面積(ji)/室內(nei)地面面積(ji))。自(zi)(zi)然(ran)照(zhao)度系(xi)(xi)數是用于評價自(zi)(zi)然(ran)光(guang)(guang)的(de)(de)照(zhao)度水平。它是反(fan)(fan)映室內(nei)的(de)(de)和(he)(he)同時從室外來的(de)(de)光(guang)(guang)照(zhao)射關系(xi)(xi)。也反(fan)(fan)映出當地光(guang)(guang)氣候(自(zi)(zi)然(ran)光(guang)(guang)能源和(he)(he)氣候的(de)(de)陽光(guang)(guang)照(zhao)度指(zhi)標的(de)(de)總和(he)(he))。
為(wei)保障人們在(zai)適宜的(de)(de)(de)光(guang)照(zhao)下生(sheng)(sheng)活,我國(guo)(guo)制定了有(you)關室(shi)內(包括(kuo)公共(gong)場所)照(zhao)度(du)的(de)(de)(de)衛生(sheng)(sheng)標準。如在(zai)公共(gong)場所商(shang)場(店(dian)(dian))的(de)(de)(de)照(zhao)度(du)衛生(sheng)(sheng)標準≥100Lx;圖書館、博物館、美術館、展覽(lan)館臺面照(zhao)度(du)的(de)(de)(de)衛生(sheng)(sheng)標準≥100Lx;公共(gong)浴(yu)室(shi)照(zhao)度(du)衛生(sheng)(sheng)標準≥50Lx;浴(yu)室(shi)(淋(lin)、池、盆浴(yu))≥30Lx,桑那浴(yu)室(shi)≥30Lx.國(guo)(guo)外有(you)關室(shi)內照(zhao)度(du)的(de)(de)(de)標準,如德國(guo)(guo)推薦幾(ji)種(zhong)額定光(guang)強(qiang),辦公室(shi)包括(kuo)文(wen)書工(gong)(gong)作(zuo)區為(wei)300Lx,打字(zi),繪圖工(gong)(gong)作(zuo)為(wei)750Lx;在(zai)工(gong)(gong)廠,生(sheng)(sheng)產線上(shang)的(de)(de)(de)視覺工(gong)(gong)作(zuo)的(de)(de)(de)照(zhao)度(du)要求為(wei)1000Lx;酒店(dian)(dian)、公共(gong)房間為(wei)200Lx;接待點、出(chu)納柜為(wei)200Lx;商(shang)店(dian)(dian)的(de)(de)(de)櫥(chu)窗為(wei)1500~2000Lx;醫(yi)院(yuan)病房為(wei)150~200Lx,緊(jin)急治療(liao)區為(wei)500Lx;學校、教(jiao)室(shi)為(wei)400~700Lx;食堂、室(shi)內健(jian)身房為(wei)300Lx等(deng)。
對于照度(du)大小(xiao)的測(ce)量(liang)(liang)方法,一(yi)般(ban)用照度(du)計(ji)測(ce)量(liang)(liang)。照度(du)計(ji)可(ke)測(ce)出(chu)不同波(bo)長的強度(du)(如對可(ke)見光波(bo)段和紫(zi)外線波(bo)段的測(ce)量(liang)(liang)),可(ke)向人們提供準確的測(ce)量(liang)(liang)結(jie)果。
總之,照(zhao)度與人體健康,尤其(qi)是對眼睛的(de)保健有著極其(qi)重要的(de)衛生學意(yi)義(yi)。
1.一般(ban)公共場所(suo)應(ying)用
為了保(bao)障人們能(neng)在適宜(yi)的光照(zhao)(zhao)下生活,我國制(zhi)定了有關(guan)室(shi)內(nei)(包括公共(gong)場所(suo)(suo))照(zhao)(zhao)度的衛生標準,運(yun)用照(zhao)(zhao)度計對各場所(suo)(suo)進(jin)行照(zhao)(zhao)度測量(liang)。
2.燈飾生產業(ye),攝影(ying)業(ye),舞臺燈光(guang)布置等(deng)
照(zhao)度計(ji)已經成(cheng)功應用到多(duo)個方案中(zhong),如(ru)燈飾(shi)生產業,攝影(ying)業,舞臺(tai)燈光布置等,不(bu)同(tong)型(xing)號(hao)照(zhao)度計(ji)可滿足不(bu)同(tong)的(de)測量要求(qiu)。
3.工(gong)廠生產流水線應用
在工(gong)廠,生產線上的(de)照(zhao)明(ming)度(du)(du)(du)要(yao)(yao)求(qiu)(qiu)比較(jiao)嚴格,連(lian)續(xu)工(gong)作會引起視覺疲勞,工(gong)作效率大打折扣,通常照(zhao)度(du)(du)(du)要(yao)(yao)求(qiu)(qiu)≥1000Lx,對于照(zhao)明(ming)度(du)(du)(du)要(yao)(yao)求(qiu)(qiu)比較(jiao)高的(de)場(chang)所可選擇大量(liang)程(cheng)的(de)照(zhao)度(du)(du)(du)計,超大量(liang)程(cheng)范圍(wei),可應對強(qiang)光線照(zhao)度(du)(du)(du)測量(liang)。
4.照度(du)計(ji)的(de)應(ying)用非常廣(guang)泛,還包括我們日常生活(huo)當中的(de)應(ying)用,比如工廠(chang)、倉庫、學校、辦公室、家庭、路(lu)燈(deng)建設、實驗室等等。
辦公(gong)室和道(dao)路(lu)及特定(ding)環境的照度標(biao)(biao)準(zhun)JIS標(biao)(biao)準(zhun)提供(gong)了適應各種(zhong)環境的照度推薦值,以(yi)下為其(qi)設定(ding)的標(biao)(biao)準(zhun)值。
1、全程跟蹤記錄照度變(bian)化情況,記錄時(shi)間長(15分鐘記錄一(yi)次數(shu)(shu)據(ju),可記錄長達5個月(yue)甚至(zhi)更長的時(shi)間),集(ji)數(shu)(shu)據(ju)采(cai)集(ji)、記錄和(he)傳輸于一(yi)體。
2、整(zheng)機(ji)功耗小,使用鋰電池(內置)供電,電池壽(shou)命可達一年以上。
3、軟件有中英文兩種版本(ben),可(ke)任意(yi)選擇,英文版具(ju)有國際通用性。
4、軟件功能(neng)強大,數據(ju)查看方便。
5、自動(dong)生成記錄(lu)曲線圖(tu),采集(ji)的數(shu)據(ju)能用(yong)EXCEL、WORD或專用(yong)軟件處理(li)。
6、記錄時間間隔(ge)從2秒至24小時任意設(she)置(zhi)。
7、體積小(58×72×29mm),操作簡單,性能(neng)可靠(適應惡劣環境(jing),失電時不丟失數據(ju))。
8、可自動報警(jing)。
顯(xian)示:3?位(wei)數(shu)字液(ye)晶顯(xian)示,最大(da)1999讀值。
電池(chi)電壓(ya)(ya)不足顯(xian)示(shi):當(dang)電池(chi)電壓(ya)(ya)低于操作電壓(ya)(ya)時,""顯(xian)示(shi)。
取樣率:2.5次(ci)/秒。
操(cao)作環境(jing):0°C至50°C,相對濕度<70%RH。
儲存(cun)環(huan)境:-20°C至(zhi)60°C,0至(zhi)80%RH(電(dian)池移除后)。
精確(que)度測試環境:23°C±5°C,相對濕度<75%RH。
尺寸:155mm(高)x48mm(寬(kuan))x24mm(厚(hou))。
電(dian)池:4顆1.5V四(si)號電(dian)池。
重量:約81.2公克(含電池)。
Lux規格:
感測(ce)器:矽質光二極體感測(ce)器
范圍:20lux,200lux,2000lux,20000lux,20fc,200fc,2000fc,20000fc
解析度(du):0.01lux,0.01fc
精確度:±(NOreading±NOdigits)
精(jing)確度:±(NOreading±NOdigits)
照度計使(shi)用的(de)機會非常廣(guang)泛,運用的(de)時機也常在不同的(de)場(chang)所(suo),所(suo)以(yi)可(ke)攜帶式體樍小(xiao)、重(zhong)量輕為照度計的(de)第一(yi)先決(jue)條件(jian)。
照度計的(de)良莠(you)與否,和它(ta)的(de)準(zhun)確度有(you)絕對的(de)關(guan)系。當然也和它(ta)的(de)價(jia)格(ge)息息相(xiang)關(guan),因此(ci)以(yi)合(he)理的(de)價(jia)格(ge)買個準(zhun)確度較高的(de)照度計實有(you)必要,一般以(yi)誤差不(bu)超過±15%為宜。
光源的(de)種(zhong)類(lei)包羅萬象(xiang),有些(xie)偏重波長(chang)(chang)較(jiao)長(chang)(chang)的(de)的(de)紅(hong)色系高壓燈,或波長(chang)(chang)較(jiao)短藍紫色系如(ru)Daylight日光燈;也有分布(bu)比(bi)較(jiao)平均(jun)的(de)如(ru)白熾燈泡系列,同(tong)一(yi)照度(du)計對不同(tong)的(de)波長(chang)(chang)其靈敏度(du)可能略有不同(tong),故適度(du)的(de)補償屬(shu)必(bi)要。
大家都知道,受照(zhao)面的(de)(de)亮度(du)(du)與光源(yuan)的(de)(de)入射(she)角(jiao)度(du)(du)有關(guan)。相同的(de)(de)道理,在用(yong)照(zhao)度(du)(du)計做測量時,感(gan)應器﹝Sensor﹞與光源(yuan)入射(she)角(jiao)度(du)(du)自然(ran)會(hui)對(dui)照(zhao)度(du)(du)計的(de)(de)讀值有影響。所(suo)以一個(ge)好(hao)的(de)(de)照(zhao)度(du)(du)計是否有余弦補償的(de)(de)功(gong)能實在不可忽(hu)略。
為了我們生活的環境更利于我們的健康,照(zhao)度(du)計的使用就成了我們的首選(xuan)。但是(shi)怎(zen)樣選(xuan)購(gou)一個適合自(zi)己的照(zhao)度(du)計呢?照(zhao)度(du)計(或稱勒克(ke)斯計)是(shi)一種專門測量光(guang)度(du)、亮度(du)的儀器儀表。一般我們在(zai)選(xuan)購(gou)的時候要考(kao)慮以下幾(ji)點:
照(zhao)度(du)(du)(du)(du)的(de)單位是一勒克斯(LUX)為(wei)、單位,用(yong)數值表示這(zhe)些場所的(de)合適(shi)光線強度(du)(du)(du)(du),以(yi)確保(bao)適(shi)應各種環境日常生(sheng)活,辦公室,工廠等(deng)所有環境均有自己的(de)"適(shi)合的(de)照(zhao)度(du)(du)(du)(du)".一旦照(zhao)度(du)(du)(du)(du)不足或者照(zhao)度(du)(du)(du)(du)過高,會因此(ci)誤認,作(zuo)業(ye)效率(lv)低下(xia),和(he)疲勞等(deng)導致視(shi)力降低等(deng)情況(kuang),當(dang)照(zhao)度(du)(du)(du)(du)適(shi)中時(shi),可提高工作(zuo)效率(lv),確保(bao)作(zuo)業(ye)安全,為(wei)此(ci)重(zhong)視(shi)照(zhao)明管(guan)理十分重(zhong)要。
使用時,必須(xu)注意避免接(jie)收很(hen)強(qiang)的(de)(de)光(guang),因為(wei)光(guang)電管(guan)陰極(ji)長期(qi)暴露在(zai)強(qiang)光(guang)下,會出(chu)現疲勞現象,使光(guang)電陰極(ji)發(fa)射(she)不正(zheng)常。所以(yi)在(zai)不用照度(du)計時要蓋好窗(chuang)口的(de)(de)保護蓋,另外紫外照度(du)計工作(zuo)的(de)(de)環(huan)境溫度(du)不能很(hen)高,也不能很(hen)低(di)。尤(you)其是(shi)采用熱電效應元件做(zuo)為(wei)接(jie)受器的(de)(de)紫外照度(du)計,對(dui)環(huan)境溫度(du)的(de)(de)要求更(geng)是(shi)嚴格(一般在(zai)20℃);而用光(guang)電管(guan)GD-5做(zuo)接(jie)受器時,對(dui)環(huan)境溫度(du)要求就不是(shi)很(hen)嚴格了(le),一般溫度(du)愈低(di)愈好;以(yi)減少暗電流.另外在(zai)測量光(guang)源的(de)(de)輻射(she)線時要垂直(zhi)于接(jie)受器的(de)(de)窗(chuang)口,如果傾斜時將產生很(hen)大的(de)(de)誤差。此時需進行角度(du)修正(zheng)。
校(xiao)準(zhun)雖不(bu)同于檢定,但進行校(xiao)準(zhun)的(de)(de)人員也應(ying)經有(you)(you)效(xiao)的(de)(de)考核,并取得(de)相應(ying)的(de)(de)合格證(zheng)書,只(zhi)(zhi)有(you)(you)持(chi)證(zheng)人員方能出具校(xiao)準(zhun)證(zheng)書和(he)校(xiao)準(zhun)報(bao)告,也只(zhi)(zhi)有(you)(you)這(zhe)種證(zheng)書和(he)報(bao)告才(cai)認(ren)為是有(you)(you)效(xiao)的(de)(de)。校(xiao)準(zhun)可以找地方計量所或者第(di)三(san)方校(xiao)準(zhun)單位,前提(ti)都必須得(de)有(you)(you)國(guo)家頒發(fa)的(de)(de)CNAS計量資(zi)質。