一、室內給排水概述
1.1室內給水
從建筑物內(nei)(nei)部(bu)結構來說,給(gei)(gei)水(shui)(shui)系(xi)統(tong)(tong)(tong)包(bao)括生活給(gei)(gei)水(shui)(shui)系(xi)統(tong)(tong)(tong)、生產(chan)給(gei)(gei)水(shui)(shui)系(xi)統(tong)(tong)(tong)、中水(shui)(shui)系(xi)統(tong)(tong)(tong)、消防給(gei)(gei)水(shui)(shui)系(xi)統(tong)(tong)(tong)、以及組合(he)給(gei)(gei)水(shui)(shui)系(xi)統(tong)(tong)(tong)。例如自(zi)動排(pai)氣(qi)(qi)閥(fa)(fa)就是(shi)屬(shu)于給(gei)(gei)水(shui)(shui)系(xi)統(tong)(tong)(tong)的(de)(de)(de)(de)。設(she)有(you)延時(shi)自(zi)閉閥(fa)(fa)的(de)(de)(de)(de)蹲式大便器的(de)(de)(de)(de)室內(nei)(nei)給(gei)(gei)水(shui)(shui)系(xi)統(tong)(tong)(tong),如學校、旅館、辦公樓等,如果在給(gei)(gei)水(shui)(shui)管(guan)(guan)系(xi)統(tong)(tong)(tong)的(de)(de)(de)(de)最頂層設(she)有(you)自(zi)閉閥(fa)(fa),最好在管(guan)(guan)系(xi)的(de)(de)(de)(de)最高點(dian)增設(she)自(zi)動排(pai)氣(qi)(qi)裝置。因為給(gei)(gei)水(shui)(shui)用的(de)(de)(de)(de)延時(shi)自(zi)閉閥(fa)(fa)能(neng)很好地(di)控制水(shui)(shui)流,但卻(que)不能(neng)很好地(di)控制氣(qi)(qi)流。當(dang)系(xi)統(tong)(tong)(tong)停水(shui)(shui)時(shi),給(gei)(gei)水(shui)(shui)管(guan)(guan)內(nei)(nei)常積存有(you)大量(liang)的(de)(de)(de)(de)空氣(qi)(qi)。系(xi)統(tong)(tong)(tong)恢復供(gong)水(shui)(shui)后,管(guan)(guan)系(xi)內(nei)(nei)空氣(qi)(qi)常會被水(shui)(shui)流壓(ya)縮(suo)至管(guan)(guan)系(xi)頂部(bu)而形(xing)成一(yi)(yi)個壓(ya)縮(suo)空氣(qi)(qi)區。此時(shi)有(you)人再(zai)按下延時(shi)自(zi)閉閥(fa)(fa)的(de)(de)(de)(de)按扭時(shi),則(ze)壓(ya)縮(suo)的(de)(de)(de)(de)空氣(qi)(qi)會伴隨著水(shui)(shui)流噴薄(bo)而出,常會將便器內(nei)(nei)的(de)(de)(de)(de)污物吹到地(di)面以上,甚至濺到入(ru)廁者的(de)(de)(de)(de)衣物上。在管(guan)(guan)系(xi)的(de)(de)(de)(de)最高點(dian)設(she)一(yi)(yi)個自(zi)動排(pai)氣(qi)(qi)閥(fa)(fa)則(ze)可有(you)效地(di)解決這一(yi)(yi)問題(ti)。
2.2室內排水
排(pai)(pai)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong)包括(kuo)生(sheng)活(huo)(huo)排(pai)(pai)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong),工業(ye)廢水(shui)(shui)(shui)(shui)排(pai)(pai)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong),以(yi)及屋面雨水(shui)(shui)(shui)(shui)排(pai)(pai)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong)。這些(xie)系(xi)統(tong)(tong)(tong)中(zhong)(zhong)包括(kuo)了水(shui)(shui)(shui)(shui)質處理(li),水(shui)(shui)(shui)(shui)質、水(shui)(shui)(shui)(shui)溫、水(shui)(shui)(shui)(shui)壓保(bao)證及供水(shui)(shui)(shui)(shui)、配(pei)水(shui)(shui)(shui)(shui)、排(pai)(pai)水(shui)(shui)(shui)(shui)、通(tong)氣等眾多(duo)技術內(nei)涵。隨(sui)著(zhu)社會(hui)的(de)(de)進步和(he)科(ke)學(xue)得到發(fa)(fa)展(zhan),室(shi)(shi)(shi)內(nei)給排(pai)(pai)水(shui)(shui)(shui)(shui)在(zai)不(bu)斷派(pai)生(sheng)出(chu)各種新(xin)的(de)(de)子(zi)系(xi)統(tong)(tong)(tong),新(xin)技術、新(xin)材料(liao)日新(xin)月異地涌現。室(shi)(shi)(shi)內(nei)給排(pai)(pai)水(shui)(shui)(shui)(shui)已成為(wei)(wei)我國現代化建(jian)設(she)中(zhong)(zhong)一支不(bu)可(ke)忽視的(de)(de)力量,在(zai)生(sheng)活(huo)(huo)中(zhong)(zhong)起著(zhu)舉足(zu)輕(qing)重(zhong)的(de)(de)作用(yong)。對于廚房和(he)廁(ce)所相鄰的(de)(de)住宅來說,如(ru)果廚、廁(ce)是單獨(du)的(de)(de)排(pai)(pai)水(shui)(shui)(shui)(shui)管(guan)系(xi)統(tong)(tong)(tong),則在(zai)最(zui)底層為(wei)(wei)兩系(xi)統(tong)(tong)(tong)作一個緊急排(pai)(pai)出(chu)聯通(tong)。從對目前(qian)我國居民的(de)(de)生(sheng)活(huo)(huo)習慣(guan)來說,下(xia)水(shui)(shui)(shui)(shui)管(guan)道發(fa)(fa)生(sheng)堵塞現象發(fa)(fa)生(sheng)的(de)(de)可(ke)能(neng)性非(fei)常(chang)大(da),也可(ke)以(yi)說只是堵的(de)(de)次(ci)數多(duo)與少的(de)(de)問題。如(ru)果室(shi)(shi)(shi)內(nei)設(she)計人員(yuan)對傳統(tong)(tong)(tong)作法稍做(zuo)改動,則可(ke)在(zai)很大(da)程度(du)上方便用(yong)戶。
二、室內給水設計
2.1生活給水系統
建筑物內應盡量利(li)用室外管網(wang)的水(shui)壓直(zhi)接供(gong)水(shui),當水(shui)壓不滿足要求時設加壓裝(zhuang)置,生活水(shui)池(chi)及其泵房設在(zai)底層,屋(wu)頂(ding)設水(shui)箱,各配水(shui)點(dian)處的靜(jing)水(shui)壓不宜大于(yu)0.45MPa,同時最高層水(shui)壓不(bu)宜小于(yu)0.10MPa,水壓(ya)大于0.35MPa的(de)人戶管,應設減壓設施,且為(wei)了利用外管網的(de)水(shui)(shui)壓,以(yi)節省能耗,一般以(yi)外管網能滿足(zu)水(shui)(shui)壓要求的(de)樓層為(wei)低壓區,空調冷卻塔的(de)補水(shui)(shui)量一般均較生活用水(shui)(shui)量大得多,因此有條(tiao)件(jian)的(de)宜(yi)將冷卻塔置(zhi)于低壓區。市政壓力不能滿足(zu)要求的(de)給(gei)水(shui)(shui)系(xi)統的(de)BA設計小區每棟單體均設有水池、水箱、水泵,由于數量多(duo),如(ru)用傳(chuan)統(tong)的(de)管理(li)方(fang)式務(wu)必造成人力、資(zi)源的(de)浪費,給管理(li)帶來很多(duo)不便,一般設計中采用BA系統(tong)對各(ge)個(ge)水(shui)池、水(shui)箱、水(shui)泵的運(yun)行狀態、故障狀態等進行監視、控制。BA系統中的(de)自動抄(chao)表系統解(jie)決(jue)了(le)人工(gong)抄(chao)表帶來的(de)諸多不(bu)便,更好地為住戶服務。給水系統的(de)BA設計主(zhu)要是通過液位、壓力、流量(liang)等訊號(hao)對加(jia)壓泵、水(shui)池、水(shui)箱運行狀態進行監(jian)視、控制(zhi)。
2.2熱水系統
住宅樓熱(re)(re)水(shui)由各自煤氣、太陽能(neng)、電熱(re)(re)水(shui)器提供(gong),公(gong)共建(jian)筑熱(re)(re)水(shui)由集中熱(re)(re)水(shui)供(gong)應系(xi)統提供(gong)。
(1)公共建筑加熱設(she)備(bei)的選擇:加熱設(she)備(bei)是(shi)熱水(shui)供(gong)應系(xi)統的核心(xin),對于熱源充足的地區(qu)采用半即熱式(shi)汽水(shui)熱交換(huan)器,它具有(you)體積(ji)小,占地小,自控(kong)精確,浮動(dong)盤管,自動(dong)除垢,自動(dong)過冷,熱水(shui)出(chu)水(shui)快(kuai),防“軍團菌”產生等優點(dian)。
(2)熱水(shui)系(xi)統的BA設計:熱水(shui)系統(tong)的(de)BA設計主(zhu)要(yao)是通(tong)過壓力、溫度信號(hao)實現對(dui)熱交換器(qi)、熱水循環泵的(de)啟停、故障(zhang),熱水溫度的(de)監(jian)視控制。
2.3給水支管的布置與敷設
給(gei)水(shui)(shui)(shui)供(gong)應系(xi)統沒(mei)有固定(ding)(ding)的(de)形式(shi),設(she)計(ji)時(shi)應根據用(yong)戶的(de)要求,結合(he)室外(wai)給(gei)水(shui)(shui)(shui)系(xi)統的(de)實(shi)際情(qing)況經技術經濟比較或采(cai)用(yong)綜(zong)合(he)評(ping)判法確定(ding)(ding)供(gong)水(shui)(shui)(shui)方式(shi)。普通住(zhu)宅(zhai)給(gei)水(shui)(shui)(shui)系(xi)統我們(men)應本著節能、便(bian)于管理的(de)原(yuan)則來選用(yong)設(she)計(ji)方案。當一(yi)戶設(she)有兩個或兩個以上衛生間,給(gei)水(shui)(shui)(shui)管道(dao)需(xu)穿越房間時(shi),橫(heng)管最(zui)好設(she)于樓板墊(dian)層(ceng)中,樓板降低7cm―l0cm,墊層采用渣或細石混凝土。當有采暖管道穿梁敷設(she)(或貼樓板下安裝),給水橫管應與采暖管道并排安裝,管道應盡量布置于客廳、餐廳等部位,這些位置是住戶裝修的重點區域,便于住戶在裝修中合理方便的處理管道。給水支管宜敷設在樓(地)面(mian)的找平層或(huo)沿墻敷設在管槽內(nei),敷設在找平層或(huo)管槽內(nei)的給(gei)水支管外(wai)徑不宜(yi)大于(yu)25mm。實際上,如果將(jiang)接往兩個或兩個以上用(yong)水(shui)點給水(shui)支管(guan)串(chuan)聯在一起,其支管(guan)外(wai)徑均會超過25mm。因(yin)此,為(wei)了滿足規范(fan)要(yao)求,給(gei)水(shui)(shui)支管(guan)人戶后即接(jie)入分水(shui)(shui)器,分水(shui)(shui)器暗設(she)于廚房或(huo)衛(wei)生(sheng)間墻(qiang)體內,通過分水(shui)(shui)器后接(jie)往各用(yong)水(shui)(shui)點,其支管(guan)外徑均可控制在(zai)25mm以下。
三、排水設計
3.1廚房排水管道的設置
廚(chu)房洗(xi)滌(di)池排水支管可(ke)(ke)直(zhi)接在(zai)樓板上接人排水立管。而對于廚(chu)房是否設地(di)(di)漏(lou),目(mu)前還存在(zai)較大爭議,建議廚(chu)房內(nei)(nei)不設地(di)(di)漏(lou):現代生活中(zhong)廚(chu)房地(di)(di)面一般已很少(shao)用水沖(chong)洗(xi),少(shao)量的濺水用抹布就可(ke)(ke)完成地(di)(di)面的清(qing)潔,廚(chu)房地(di)(di)漏(lou)由(you)于長時(shi)間(jian)無(wu)水補充,水封內(nei)(nei)存水蒸發后(hou)臭氣(qi)反由(you)地(di)(di)漏(lou)進(jin)(jin)入(ru)室內(nei)(nei)。同時(shi),取(qu)消地(di)(di)漏(lou)還可(ke)(ke)避(bi)免地(di)(di)漏(lou)排水支管進(jin)(jin)入(ru)下層戶內(nei)(nei)空間(jian)。
3.2衛生間排水管道的設置
新設計的住(zhu)宅應致力于(yu)取消伸入(ru)下層住(zhu)戶空間的排(pai)水(shui)橫管(guan),具體做(zuo)法有:
(1)使衛(wei)生間地板面下沉,管道(dao)敷設在填渣層中(zhong)。
(2)使衛生間地(di)板(ban)面(mian)不下沉,而使用P形坐便器(后出口式(shi)),使得(de)下(xia)水管(guan)在本層與(yu)立管(guan)銜接。地漏采(cai)用側(ce)壁式(shi),洗臉盆、浴缸等排(pai)水管(guan)也在地面以(yi)(yi)上(shang)敷設與(yu)立管(guan)銜接。這兩種做(zuo)法(fa)均可以(yi)(yi)使下(xia)水管(guan)道(dao)每層水平(ping)分隔開,若需要(yao)檢修可以(yi)(yi)獨戶進行,不(bu)影響鄰(lin)居。
(3)地(di)漏與存水彎的(de)配合問題,傳統鐘罩(zhao)式地(di)漏的(de)水封(feng)容易揮發,常常造成下水道異味和排水口溢出的(de)液體進入室內,形成室內污(wu)染。所(suo)以(yi)在給排水設計中(zhong),必須重視這個問題。
3.3污水系統
室內一(yi)般糞便污(wu)水(shui)(shui)(shui)和(he)其(qi)他(ta)廢(fei)水(shui)(shui)(shui)合流(liu),高層(ceng)(ceng)建筑(zhu)的(de)(de)生活污(wu)水(shui)(shui)(shui)立(li)管設(she)置(zhi)專用(yong)(yong)通(tong)氣立(li)管,糞便污(wu)水(shui)(shui)(shui)經(jing)室外(wai)化糞池(chi)處理后(hou)排(pai)入市政(zheng)排(pai)水(shui)(shui)(shui)管網,職工食堂和(he)營業的(de)(de)含油污(wu)水(shui)(shui)(shui)單獨設(she)隔油處理。為(wei)改善底(di)層(ceng)(ceng)排(pai)水(shui)(shui)(shui)條件,采用(yong)(yong)底(di)層(ceng)(ceng)污(wu)水(shui)(shui)(shui)獨立(li)出戶,地下室污(wu)水(shui)(shui)(shui)設(she)污(wu)水(shui)(shui)(shui)集水(shui)(shui)(shui)坑及潛污(wu)泵(beng),經(jing)提升后(hou)排(pai)至室外(wai)。為(wei)減少投資,方便管理,除(chu)規(gui)模很(hen)大的(de)(de)建筑(zhu)群或有關部門提出明(ming)確的(de)(de)要(yao)求(qiu)需要(yao)做中水(shui)(shui)(shui)設(she)計外(wai),一(yi)般小規(gui)模的(de)(de)中水(shui)(shui)(shui)系統,由于管理等(deng)問題(ti),運行情(qing)況都不太好(hao)。
3.4給排水管道的設計
給排水立管應盡量置于同一個位置,最好位于通風道附近,以便于住戶進行裝修包裹。在有條件時最好設置管道井,可以將水表設于其中以做到水表出戶。當一戶設有兩個或兩個以上衛生間,給水管道需要穿越房間時,橫管(管徑小(xiao)于De25)最好設于樓板面找(zhao)平層中。
四、結語
室內給(gei)排水(shui)系統(tong)看(kan)似簡(jian)單,但它與居民的日(ri)常生活(huo)息(xi)息(xi)相關。作為給(gei)排水(shui)設(she)計(ji)人(ren)員,應本著技術、安全(quan)、美觀(guan)、實用、經濟的原則,在實踐中努力創新,尋求最佳的給(gei)排水(shui)設(she)計(ji)方(fang)案,適應住宅設(she)計(ji)發展的新要求,滿(man)足人(ren)民群眾不斷(duan)提高的物質文化和生活(huo)要求。