消防應急燈的種類有很多,一般場所常用的應急燈為LED雙頭應(ying)(ying)急(ji)(ji)(ji)燈(deng)和(he)安全出口指示燈(deng),應(ying)(ying)急(ji)(ji)(ji)燈(deng)作為一(yi)種普通(tong)的(de)照明工具(ju),但其發揮(hui)的(de)作用(yong)卻很大。應(ying)(ying)急(ji)(ji)(ji)燈(deng)工作方式分為市電(dian)(dian)和(he)備電(dian)(dian)兩塊,內部安裝有小型蓄電(dian)(dian)池(chi),當(dang)市電(dian)(dian)斷電(dian)(dian)時自動(dong)轉換(huan)備電(dian)(dian)工作,使(shi)消防應(ying)(ying)急(ji)(ji)(ji)燈(deng)在(zai)斷電(dian)(dian)的(de)情況下(xia)還能(neng)繼續(xu)正常使(shi)用(yong),根據新國標(biao),應(ying)(ying)急(ji)(ji)(ji)燈(deng)斷電(dian)(dian)后的(de)工作時間不能(neng)少于(yu)90分鐘以上(shang)。
1、按應急供電形式分為:
a)自帶電源(yuan)型;
b)集中電源(yuan)型;
c)子母電源型(xing)。
2、按用途分為:
a)雙頭消防應急燈
此款雙(shuang)頭消防應急(ji)燈,可以長(chang)時間應急(ji),是工(gong)程(cheng)、超市、商場等公眾場所的首(shou)選!
b)消防應(ying)急標志燈
消防應(ying)急標(biao)(biao)志(zhi)燈根(gen)據安(an)裝方(fang)式的要求,分別(bie)有壁(bi)裝、吊裝、嵌裝及地埋式等幾(ji)種安(an)裝方(fang)式。燈具表面圖形(xing)分別(bie)有左向(xiang)指(zhi)示(shi)、右(you)向(xiang)指(zhi)示(shi)、左右(you)向(xiang)指(zhi)示(shi)、安(an)全出口(kou)指(zhi)示(shi)和樓(lou)層指(zhi)示(shi)。提(ti)醒人們建筑逃生(sheng)通(tong)道出口(kou)的方(fang)向(xiang)。消防應(ying)急標(biao)(biao)志(zhi)燈一般為常亮狀態(tai)。
c)、消防應急照明標志燈
消(xiao)防(fang)應急照(zhao)明標志(zhi)燈,即一體燈。一般常用的消(xiao)防(fang)應急照(zhao)明標志(zhi)燈選(xuan)用工業塑(su)料和(he)高(gao)亮度的燈泡制成(cheng),顏色以白色為主,表面(mian)有兩個箭頭,材料不老(lao)化、散熱快、抗沖擊(ji)等(deng)特點。
3、按工作方式分為:
a)持續型;
b)非持續型。
4、按應急實現方式分為:
a)獨立型;
b)集中控制型;
c)子母控(kong)制型(xing)。
1、雙頭(tou)消(xiao)防(fang)應(ying)急燈(deng)
此款安全出口指示燈擁有語音故障報警系統,可以超(chao)長(chang)應急時(shi)間,是工程、超(chao)市、商場(chang)等公眾場(chang)所(suo)的(de)首選!
2、消防應(ying)急燈出(chu)口一體(ti)燈(多功能兩用)
一體燈采用接線(xian)最長(chang)55CM長市場一(yi)般才30CM左右一體燈采(cai)用獨特設計功能,停電時不用可(ke)以同時關閉要用時可(ke)以開啟。
3、防暴型應急燈(deng)
防(fang)爆(bao)標(biao)志(zhi):ExdIIBT6防護等(deng)級:IP54適用于石(shi)油開采、化工、軍(jun)工等易(yi)燃易(yi)爆危險(xian)場所和環境(jing)作停電時應急安全(quan)疏散和照(zhao)明。
常見形式有手提應(ying)急(ji)燈(deng)(deng)、消防(fang)應(ying)急(ji)燈(deng)(deng)、節能(neng)(neng)應(ying)急(ji)燈(deng)(deng)、供應(ying)應(ying)急(ji)燈(deng)(deng)、水下應(ying)急(ji)燈(deng)(deng)、可充電(dian)應(ying)急(ji)燈(deng)(deng)、太陽能(neng)(neng)應(ying)急(ji)燈(deng)(deng)、多(duo)功能(neng)(neng)應(ying)急(ji)燈(deng)(deng)等(deng)。
國內目前使(shi)(shi)用的(de)應急照明系統以自帶電(dian)(dian)(dian)(dian)源獨立控制型為主,正常(chang)電(dian)(dian)(dian)(dian)源接自普通照明供電(dian)(dian)(dian)(dian)回路中,平時對應急燈蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)充(chong)(chong)電(dian)(dian)(dian)(dian),當(dang)正常(chang)電(dian)(dian)(dian)(dian)源切斷時,備用電(dian)(dian)(dian)(dian)源(蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi))自動(dong)供電(dian)(dian)(dian)(dian)。這種形式的(de)應急燈每個燈具內部都有變壓、穩壓、充(chong)(chong)電(dian)(dian)(dian)(dian)、逆變、蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)等(deng)大量的(de)電(dian)(dian)(dian)(dian)子元器(qi)件,應急燈在使(shi)(shi)用、檢修、故障時電(dian)(dian)(dian)(dian)池(chi)(chi)均需充(chong)(chong)放電(dian)(dian)(dian)(dian)。
另一種是集中(zhong)(zhong)電(dian)源集中(zhong)(zhong)控制(zhi)型(xing),應急(ji)燈(deng)(deng)具內(nei)無獨立電(dian)源,正常(chang)照明電(dian)源故(gu)障(zhang)時,由集中(zhong)(zhong)供(gong)(gong)電(dian)系(xi)統(tong)(tong)供(gong)(gong)電(dian)。在這種形(xing)式的應急(ji)照明系(xi)統(tong)(tong)中(zhong)(zhong),所有燈(deng)(deng)具內(nei)部(bu)復雜的電(dian)子電(dian)路被省掉了,應急(ji)照明燈(deng)(deng)具與普通的燈(deng)(deng)具無異,集中(zhong)(zhong)供(gong)(gong)電(dian)系(xi)統(tong)(tong)設置(zhi)在專用的房間(jian)內(nei)。
與(yu)自帶電(dian)(dian)源(yuan)獨(du)立控制(zhi)型應(ying)急(ji)(ji)燈(deng)(deng)(deng)(deng)具(ju)(ju)(ju)相比,集中(zhong)電(dian)(dian)源(yuan)集中(zhong)控制(zhi)型應(ying)急(ji)(ji)燈(deng)(deng)(deng)(deng)具(ju)(ju)(ju)有(you)便(bian)于集中(zhong)管(guan)理、用(yong)(yong)戶自查(cha)、消(xiao)防(fang)監(jian)督檢查(cha)、延長燈(deng)(deng)(deng)(deng)具(ju)(ju)(ju)壽(shou)命、提(ti)高應(ying)急(ji)(ji)疏(shu)散效能等(deng)優點,系(xi)統可靠性好、使用(yong)(yong)壽(shou)命長、維護與(yu)管(guan)理方便(bian)、系(xi)統價格低。但是(shi)集中(zhong)電(dian)(dian)源(yuan)集中(zhong)控制(zhi)型應(ying)急(ji)(ji)燈(deng)(deng)(deng)(deng)具(ju)(ju)(ju)由于每(mei)個(ge)應(ying)急(ji)(ji)燈(deng)(deng)(deng)(deng)具(ju)(ju)(ju)內沒(mei)有(you)備(bei)用(yong)(yong)電(dian)(dian)源(yuan)(蓄電(dian)(dian)池),若供(gong)(gong)電(dian)(dian)線(xian)路發生故障(zhang),則會直接影響(xiang)到(dao)應(ying)急(ji)(ji)照(zhao)明系(xi)統的(de)正(zheng)常運行,所以對(dui)其(qi)供(gong)(gong)電(dian)(dian)線(xian)路敷設有(you)特(te)殊的(de)防(fang)火要求。而自帶電(dian)(dian)源(yuan)獨(du)立控制(zhi)型應(ying)急(ji)(ji)燈(deng)(deng)(deng)(deng)具(ju)(ju)(ju)因為(wei)在(zai)每(mei)個(ge)應(ying)急(ji)(ji)燈(deng)(deng)(deng)(deng)具(ju)(ju)(ju)內都帶有(you)備(bei)用(yong)(yong)電(dian)(dian)源(yuan)(蓄電(dian)(dian)池),所以對(dui)供(gong)(gong)電(dian)(dian)線(xian)路沒(mei)有(you)特(te)殊的(de)要求,供(gong)(gong)電(dian)(dian)線(xian)路故障(zhang)并(bing)不會影響(xiang)到(dao)備(bei)用(yong)(yong)電(dian)(dian)源(yuan)發生作用(yong)(yong)。應(ying)急(ji)(ji)燈(deng)(deng)(deng)(deng)發生故障(zhang)時一般(ban)也只影響(xiang)該燈(deng)(deng)(deng)(deng)具(ju)(ju)(ju)本身,對(dui)整個(ge)系(xi)統影響(xiang)不大。
在選(xuan)擇應(ying)(ying)急(ji)(ji)照(zhao)明燈時,應(ying)(ying)根(gen)據具體情(qing)況合(he)理選(xuan)擇應(ying)(ying)急(ji)(ji)照(zhao)明系統。一般來說,新建工程或(huo)設(she)有消防控(kong)(kong)制室(shi)的工程,應(ying)(ying)盡量在建設(she)過程中統一布線(xian),選(xuan)用集(ji)中電源集(ji)中控(kong)(kong)制型應(ying)(ying)急(ji)(ji)照(zhao)明;對(dui)于小型場(chang)所、后期整(zheng)改或(huo)二次(ci)裝潢(huang)改造的工程應(ying)(ying)選(xuan)用自帶(dai)電源獨立控(kong)(kong)制型應(ying)(ying)急(ji)(ji)照(zhao)明。
(一)應急燈常(chang)用的(de)幾種接線方式
在日常監督檢查(cha)中(zhong)發現,由于接(jie)線方式錯誤導致應急照(zhao)明燈具(ju)不能正(zheng)常使(shi)用的情況很普(pu)遍。
(二)注意事項
1、對各(ge)種接線方(fang)式的特(te)點要準確掌握,以免盲目接線,起(qi)不了(le)應(ying)有作用;
2、應急照明如(ru)果(guo)做(zuo)為平時照明的一部分,應采用(yong)三線式(shi)可控接法。
3、對于(yu)多層公共建筑,如果沒有設置消控(kong)(kong)中心,各個部位(wei)的(de)應急照明燈(deng)具可以采用加就地開關控(kong)(kong)制(單燈(deng)單控(kong)(kong)或多燈(deng)控(kong)(kong)制)或配電(dian)箱(xiang)內(nei)集中控(kong)(kong)制的(de)三(san)線式接法(fa)。
4、有消(xiao)防控制(zhi)中(zhong)心的(de)工程,為了滿足當(dang)火災(zai)發生時,消(xiao)控中(zhong)心能開通火災(zai)層和相關(guan)層消(xiao)防應急照明(ming)的(de)要求。
1、在工(gong)程設計中,為了(le)方便平時(shi)維護與管理,消防應(ying)急照(zhao)明最好按層以專用饋電回路(lu)供電。
2、為保(bao)證消(xiao)防應急(ji)照明供(gong)電電源(yuan)的可靠,有條件(jian)的應由變(bian)電所的低壓應急(ji)母線段供(gong)電,即當用柴油發電機(ji)組(zu)做應急(ji)電源(yuan)時,只要發電機(ji)投入使用,它(ta)就(jiu)有電繼續保(bao)證供(gong)電。
3、在火災狀(zhuang)態下,靠(kao)近地面的(de)煙少、氧氣(qi)多,人(ren)疏散的(de)本能反應(ying)是彎腰或匍匐前進,因而局部(bu)高照(zhao)度照(zhao)明比高位
安裝帶來的均勻照(zhao)度(du)更為有效。所以應提倡低(di)位安裝,即在(zai)靠近(jin)地面或在(zai)地面高度(du)上提供疏散應急照(zhao)明。
4、應(ying)急燈均(jun)以放電狀態出廠(chang),使用前必須進行(xing)20 小時的充電,才可進行(xing)放電。
5、使用(yong)中的應急燈具應定期進(jin)行性(xing)能檢查,每半(ban)個(ge)月(yue)或一個(ge)月(yue)通過連續開(kai)關(guan)試驗,以(yi)檢查電(dian)(dian)路(lu)轉(zhuan)換及電(dian)(dian)池的應急功能,并進(jin)行放電(dian)(dian),以(yi)延長電(dian)(dian)池使用(yong)壽命。
6、做好配(pei)電線路的防火(huo)(huo)保(bao)護,暗敷時(shi)敷設在非燃燒體結構內,保(bao)護層厚度不小于30mm;明敷時(shi)穿(chuan)金屬(shu)管(guan),并(bing)在鋼管(guan)外面刷防火(huo)(huo)涂料或采(cai)用其它防火(huo)(huo)措施;線路采(cai)用防火(huo)(huo)電纜或耐火(huo)(huo)電纜、電線。
應急燈一般都是(shi)設計(ji)為(wei)長方體(ti)造型,帶遠距離探(tan)照(zhao)功能(neng)和近距離大范圍照(zhao)亮功能(neng)。品(pin)質好(hao)的LED應急燈,一般都是(shi)白光的,而(er)且絕對沒(mei)有頻閃,所以對眼睛還是(shi)好(hao)的。并(bing)且攜帶方便,可(ke)在家中隨意(yi)移(yi)動(dong),也(ye)可(ke)攜帶到野外(wai)去(qu)野營(ying)之用。
而普(pu)通臺燈或充電臺燈平常見得比較多,也就不多說,一般都沒遠距離探照功能,而且(qie)攜帶沒應急(ji)方便。