質量隱患
如材(cai)料(liao)(liao)選擇不(bu)當(dang)、管(guan)(guan)道(dao)配(pei)置不(bu)合理、管(guan)(guan)道(dao)布置不(bu)規范、不(bu)進行(xing)水壓試(shi)驗(yan)、預留管(guan)(guan)口尺寸不(bu)準、排水管(guan)(guan)亂用材(cai)料(liao)(liao)、排水管(guan)(guan)安裝距(ju)離太長(chang)、不(bu)進行(xing)通(tong)水試(shi)驗(yan)、地漏的坡度倒置等。
質量選材
客廳、臥室、衛生(sheng)間(jian)(jian)、陽臺、廚(chu)房燈不同功(gong)能空(kong)間(jian)(jian)的(de)用(yong)(yong)水(shui)(shui)(shui)(shui)需求存在一定(ding)的(de)差異。比(bi)如(ru)廚(chu)房主要(yao)考慮(lv)冷熱(re)水(shui)(shui)(shui)(shui)管(guan)的(de)接入,凈(jing)水(shui)(shui)(shui)(shui)器的(de)安(an)裝;客廳則(ze)重點(dian)考慮(lv)選用(yong)(yong)什(shen)么飲水(shui)(shui)(shui)(shui)方(fang)式的(de)用(yong)(yong)水(shui)(shui)(shui)(shui)方(fang)案(an);衛生(sheng)間(jian)(jian)則(ze)要(yao)考慮(lv)馬桶、盥洗池、淋浴的(de)用(yong)(yong)水(shui)(shui)(shui)(shui)問題,包括水(shui)(shui)(shui)(shui)質(zhi)、水(shui)(shui)(shui)(shui)壓、水(shui)(shui)(shui)(shui)溫等主要(yao)內(nei)容。
設計規范
1、所有材料(liao)應符合國(guo)家標準(zhun);
2、根(gen)據潔具(ju)準(zhun)確定位出(chu)水口及排水口位置;
3、冷(leng)(leng)熱(re)水管(guan)排列時(shi),應做到左熱(re)右(you)冷(leng)(leng),上熱(re)下冷(leng)(leng);
施工要求標準
1、走頂不走地
水路(lu)鋪設可(ke)走(zou)頂,也可(ke)走(zou)地。兩(liang)種布設管路(lu)的方式(shi)也各有利弊,走(zou)頂費管、走(zou)地省料;走(zou)頂便于檢修,走(zou)地漏水難以發(fa)覺,處(chu)理(li)困難。建議在預算相對充足的情況下,優先選擇走(zou)頂布局方式(shi)。
2、水下電上
當水(shui)管、電(dian)路(lu)(lu)管線(xian)同時布(bu)置在一個空間內,水(shui)路(lu)(lu)管線(xian)要居(ju)于電(dian)路(lu)(lu)線(xian)路(lu)(lu)之下,水(shui)管漏(lou)水(shui)也不會影響(xiang)到(dao)用電(dian)安(an)全。
3、水管布設順序
一般按照“左熱(re)右冷、上(shang)熱(re)下冷”的順序布設(she)即可。
4、冷熱不同槽、水電不同槽
冷(leng)水(shui)、熱(re)(re)水(shui)同槽(cao)會(hui)相(xiang)互影響,熱(re)(re)水(shui)管變(bian)冷(leng)、冷(leng)水(shui)管升(sheng)溫。水(shui)電(dian)不同槽(cao)主要是防止漏(lou)電(dian)、短路等(deng)問題的出(chu)現。
驗收標準
1、水管的安裝以距(ju)離(li)近、接口小(xiao)為(wei)最佳狀(zhuang)態,中直(zhi)整(zheng)齊,在鋪排中應(ying)盡量減(jian)少彎曲(qu)和交疊。
2、不同(tong)位(wei)置水管類(lei)型有別
(1)室內水(shui)管(guan)應全部用銅管(guan)(PVC管(guan));
(2)熱水管一般采用(yong)包(bao)膠(jiao)銅管;
(3)下水管一(yi)般采用PVC管,接口(kou)要(yao)用生料(liao)帶。
3、廚房(fang)、廁所要有下(xia)水(shui)(shui)(shui)口(kou)(地漏),排水(shui)(shui)(shui)防水(shui)(shui)(shui)措施到位
地(di)(di)(di)(di)(di)漏(lou)雖然小,但它對(dui)居家健康的影(ying)響(xiang)卻(que)不小,房間(jian)內有下水道(dao)異味都(dou)是地(di)(di)(di)(di)(di)漏(lou)的原因。地(di)(di)(di)(di)(di)下管道(dao)充滿各種腐壞產生的氣體(ti)從地(di)(di)(di)(di)(di)漏(lou)返味,且討厭(yan)的蟑螂(lang)之(zhi)類的蟲也會經(jing)由地(di)(di)(di)(di)(di)漏(lou)從下水道(dao)之(zhi)中爬(pa)到你(ni)家中。所以(yi)要注意選擇防(fang)臭防(fang)蟲的地(di)(di)(di)(di)(di)漏(lou)。
4、額外注意龍頭水管
對于龍頭水管等,不僅要注(zhu)意水管接(jie)口(kou)、滲漏與否,還要注(zhu)意表面及配件(jian)有無(wu)損(sun)壞。
5、安裝后要試水
所(suo)有(you)水管安(an)裝(zhuang)完畢后要試水,不能有(you)滲水、漏水現象。
驗收注意
1、排水管(guan)(guan)道應(ying)在施工(gong)前對(dui)原有管(guan)(guan)道臨(lin)時封(feng)口,避免雜物進入管(guan)(guan)道。
2、水管安裝不(bu)得靠近電源(yuan),水管與燃氣管的間距應不(bu)小(xiao)于50mm。
質量隱患
電路沒有接(jie)地保護、電(dian)路回路簡單、電(dian)路設備老化嚴重、開(kai)關插座不夠用等。
質量選材
1、電線的外包裝上一定(ding)要有明確的產品標識;
2、電(dian)線的內(nei)芯(xin)是導電(dian)的關鍵,內(nei)芯(xin)應該厚實且(qie)均(jun)勻;
3、它的外層(ceng)塑料(liao)則(ze)起著大作用。應該(gai)選擇塑料(liao)皮光(guang)澤(ze)鮮亮的,而且質地較細密的。
設計規范
1、根據電(dian)(dian)路的用途(tu)進行(xing)電(dian)(dian)路定位。比如,開關、插(cha)座、燈等根據要求進行(xing)定位。
2、據定位和電(dian)路(lu)走向,開布線(xian)(xian)槽(cao)。線(xian)(xian)路(lu)槽(cao)很有講究(jiu),要(yao)橫(heng)平豎直(zhi)。不過,規范(fan)的(de)做法是(shi)盡(jin)量少開橫(heng)槽(cao),會影響(xiang)墻(qiang)的(de)承受力。
3、為(wei)防止信號干(gan)擾,強弱電的(de)間(jian)距應為(wei)500mm,但很多施工(gong)達不到(dao)這個標準。
施工要求標準
1、設計(ji)布(bu)線(xian)時,應遵循強電走上、弱電在下、橫平(ping)豎直(zhi)、避免交叉、美觀實用的原則。
2、所(suo)有線(xian)路都必須為活線(xian)。接電(dian)(dian)線(xian)時要(yao)注意,不得(de)隨(sui)意引(yin)線(xian)。電(dian)(dian)源線(xian)配線(xian)時,所(suo)用(yong)導線(xian)應與用(yong)電(dian)(dian)設備的最(zui)大輸(shu)出功率相匹配。
3、強、弱(ruo)電線不得在同一管內(nei)敷設,不得進同一接線盒(he),其間距(ju)不得小于(yu)300毫米。
驗收標準
1、開關、暗(an)盒定(ding)位按(an)工(gong)程(cheng)要(yao)求必須對稱、縱橫一(yi)致。
2、電線接頭牢(lao)固無松動,用(yong)雙層絕緣膠布緾緊,并在接頭處(chu)留有檢修口。
3、檢查所有(you)燈具開(kai)關是(shi)否靈(ling)活(huo),插座面板有(you)無松動,杜絕導(dao)電、漏電發(fa)生(sheng)。
4、每組電(dian)路回路清楚可靠,符(fu)合用電(dian)要求,火線(xian)、零線(xian)、電(dian)線(xian)要分色(se)或(huo)有(you)明顯標記。
驗收注意
1、強電線管走墻,弱(ruo)電線管走地(或者(zhe)地面(mian)強弱(ruo)電線管走地,但必(bi)須分(fen)開(kai)300mm以上),水(shui)管盡(jin)可能走墻,線槽應橫平豎直。
2、暗線(xian)敷設必須(xu)配(pei)管,空(kong)心樓板除外(wai)(空(kong)心樓板用護套線(xian)),強弱電不能穿入同(tong)一(yi)根管內。管內電線(xian)應處于寬松狀態(tai)。
3、電(dian)線管(guan)內不得有(you)接頭,在水電(dian)完工后,所有(you)開關、插座的明露線頭必(bi)須用(yong)絕緣膠布(bu)包(bao)好,以免發生觸電(dian)危險。
4、安(an)裝電源插座(zuo)時,應左零右(you)相(火),上(shang)方為(wei)地線(xian)。火線(xian)進開(kai)關(guan),零線(xian)進燈(deng)頭。
5、同一室內的電(dian)(dian)源、電(dian)(dian)話(hua)、電(dian)(dian)視等插(cha)座(zuo)面板應(ying)在同一水平標高上,高差(cha)應(ying)小于5mm。
質量選材
實木地(di)板(ban):隔音隔熱、冬暖夏(xia)涼(liang)、華麗高貴,但價格貴、耐磨(mo)差(cha)、表面氧化(hua)、抗(kang)沖擊力(li)差(cha)。
多(duo)層(ceng)復合地板(ban):耐磨性強(qiang)、經(jing)久耐用、價格中等、腳感舒適,但(dan)有少量甲醛。
強化復合地板:耐磨、樣(yang)式(shi)多、抗沖擊、抗靜電(dian)、安裝方(fang)便(bian),但水(shui)泡損壞后(hou)不可(ke)修復,腳感較(jiao)差(cha)、含有少量甲(jia)醛。
竹(zhu)地板:性能(neng)優越(yue)、不(bu)易(yi)變形(xing)、冬暖(nuan)夏涼、價格便宜(yi)、安(an)裝方便、保養簡單,但易(yi)脫落、易(yi)分層、不(bu)防水(shui)、不(bu)能(neng)用于地暖(nuan)。
設計規范
1、鋪裝前(qian):鋪裝實木地(di)板前(qian)需(xu)要保證基礎地(di)面(mian)平整(zheng),不會坑(keng)坑(keng)洼洼,沒有(you)相差(cha)很多(duo)的高低不平,一(yi)般(ban)是直(zhi)徑2m范圍內高低差(cha)在3mm以內;
2、鋪裝(zhuang)過(guo)程:鋪裝(zhuang)過(guo)程中需要(yao)(yao)注(zhu)意(yi)地面不能有顆(ke)粒(li)狀的(de)固(gu)體,如果是平(ping)扣(kou)的(de)需要(yao)(yao)打木地板(ban)專用D3膠(jiao)水,墻邊需要(yao)(yao)預(yu)留伸縮縫,并且用玻璃膠(jiao)收口。
3、鋪(pu)裝完(wan)成后(hou):鋪(pu)裝完(wan)成后(hou)需要檢查地板是(shi)(shi)否(fou)平(ping)整,踩上去是(shi)(shi)否(fou)會(hui)出現(xian)硌腳和(he)凹凸(tu)不(bu)平(ping)的(de)感(gan)覺(jue),檢查墻邊(bian)是(shi)(shi)否(fou)有(you)用玻(bo)璃膠收(shou)口(kou),門(men)口(kou)等(deng)地方的(de)壓邊(bian)條是(shi)(shi)否(fou)裝好。
驗收標準
1、地板鋪裝驗(yan)收:檢驗(yan)地(di)(di)(di)板(ban)表面(mian)平整度,使用兩(liang)米(mi)(mi)(mi)的靠尺(chi)和塞尺(chi)進(jin)行驗(yan)收,標(biao)準是每2米(mi)(mi)(mi)內(nei)誤差(cha)值在0.3毫(hao)(hao)米(mi)(mi)(mi)內(nei);檢驗(yan)兩(liang)塊兒地(di)(di)(di)板(ban)之間(jian)拼縫的高度差(cha),標(biao)準為(wei)≤0.6毫(hao)(hao)米(mi)(mi)(mi);檢驗(yan)兩(liang)塊地(di)(di)(di)板(ban)之間(jian)的拼縫間(jian)隙,標(biao)準為(wei)≤0.8毫(hao)(hao)米(mi)(mi)(mi);檢驗(yan)地(di)(di)(di)板(ban)與墻面(mian)及地(di)(di)(di)面(mian)固定物(如暖氣(qi)管道)之間(jian)的間(jian)隙,標(biao)準為(wei)8毫(hao)(hao)米(mi)(mi)(mi)—12毫(hao)(hao)米(mi)(mi)(mi)之間(jian);檢驗(yan)地(di)(di)(di)板(ban)表面(mian)光(guang)滑,漆面(mian)無(wu)損傷(shang)、無(wu)明顯劃痕;主要(yao)行走區域內(nei)無(wu)明顯異(yi)響。
2、踢腳(jiao)(jiao)線(xian)的驗收:踢腳(jiao)(jiao)線(xian)與(yu)門(men)框間(jian)隙≤2毫(hao)(hao)(hao)米(mi)(mi);踢腳(jiao)(jiao)線(xian)拼縫之間(jian)間(jian)距≤1毫(hao)(hao)(hao)米(mi)(mi);踢腳(jiao)(jiao)線(xian)與(yu)地板表(biao)面的間(jian)隙應(ying)該在3毫(hao)(hao)(hao)米(mi)(mi)到5毫(hao)(hao)(hao)米(mi)(mi)范圍內;踢腳(jiao)(jiao)線(xian)扣口的高(gao)度差應(ying)≤1毫(hao)(hao)(hao)米(mi)(mi)。
3、門(men)扣(kou)(kou)條的(de)(de)驗收:門(men)扣(kou)(kou)條應裝(zhuang)(zhuang)在(zai)門(men)的(de)(de)正下方,關閉(bi)門(men)后里外都不留邊(bian)為宜,扣(kou)(kou)條和門(men)的(de)(de)底部(bu)間隙在(zai)3毫米(mi)—7毫米(mi)之(zhi)間,門(men)能開閉(bi)自如。扣(kou)(kou)條的(de)(de)安裝(zhuang)(zhuang)要牢固、穩定,可以用腳踢一下扣(kou)(kou)條的(de)(de)中間部(bu)位,檢查扣(kou)(kou)條兩邊(bian)是(shi)否翹(qiao)。
質量選材
1、基層底板(ban)(ban)一般(ban)選用(yong)膠合(he)板(ban)(ban)或人造板(ban)(ban),當選用(yong)厚木板(ban)(ban)時,需在板(ban)(ban)背面(mian)開卸力槽,以防板(ban)(ban)材變形。
2、骨架料一般用紅白松烘(hong)干(gan)料,含水率(lv)大于12%,厚度應根據設(she)計要求(qiu),且不得有腐朽、節(jie)疤、劈(pi)裂(lie)、扭曲等(deng)疵病(bing),還要預先(xian)經防腐處理。
3、面(mian)板一般采用(yong)膠合板,厚度(du)不小于3mm,顏色、花紋要盡量(liang)相似。用(yong)原木板材作面(mian)板時,要采用(yong)烘(hong)干的進口實木,含水率不大于12%。
4、木貼臉(lian)一般(ban)采用工(gong)廠加工(gong)的(de)半成(cheng)品。
設計規范
安裝護(hu)墻板(ban)時(shi)(shi),木板(ban)的(de)年輪(lun)凸面(mian)應(ying)向內放置,相(xiang)鄰面(mian)板(ban)的(de)木紋(wen)和色澤應(ying)近似。裁板(ban)時(shi)(shi)要(yao)略(lve)大于(yu)龍(long)骨(gu)架的(de)實際(ji)尺(chi)寸(cun),大面(mian)凈(jing)兆,小面(mian)刨直,木紋(wen)根部向下,長度(du)方(fang)向需(xu)要(yao)對接時(shi)(shi),花紋(wen)應(ying)通順,其接頭位置應(ying)避開視線平視范圍,配好的(de)面(mian)板(ban)要(yao)刨凈(jing)光,經試裝合適后,在護(hu)墻板(ban)背面(mian)貼一(yi)層防潮紙,即可正式安裝。
驗收標準
需要(yao)檢查(cha)門(men)窗洞口是否(fou)(fou)方(fang)正垂(chui)直,預埋木(mu)磚或連(lian)接鐵件是否(fou)(fou)符合(he)要(yao)求,護(hu)(hu)墻(qiang)(qiang)(qiang)板(ban)應(ying)(ying)根據(ju)設(she)計要(yao)求事先(xian)彈出安裝高度(du)的(de)水(shui)平(ping)線,局部木(mu)護(hu)(hu)墻(qiang)(qiang)(qiang)板(ban)根據(ju)高度(du)和(he)房間(jian)大(da)(da)小,做成龍(long)骨(gu)(gu)架(jia),整體或分(fen)(fen)牌(pai)安裝,高木(mu)護(hu)(hu)墻(qiang)(qiang)(qiang)板(ban)根據(ju)房間(jian)四角和(he)上下(xia)龍(long)骨(gu)(gu)先(xian)找(zhao)平(ping)、找(zhao)直,按面板(ban)分(fen)(fen)塊大(da)(da)小由上到下(xia)做好木(mu)標筋,然后在空(kong)檔內(nei)根據(ju)設(she)計要(yao)求釘(ding)(ding)(ding)橫豎龍(long)骨(gu)(gu),安裝木(mu)龍(long)骨(gu)(gu)必須找(zhao)方(fang)找(zhao)直,除預留出板(ban)面厚度(du)外,骨(gu)(gu)架(jia)與(yu)木(mu)磚間(jian)的(de)空(kong)隙應(ying)(ying)墊以木(mu)墊,用釘(ding)(ding)(ding)子釘(ding)(ding)(ding)牢,每塊木(mu)磚至少(shao)釘(ding)(ding)(ding)兩(liang)個(ge)釘(ding)(ding)(ding)子。
質量選材
1、實木(mu)材(cai)料:實木(mu)材(cai)料的(de)門窗套安裝起來特別(bie)的(de)方(fang)便簡潔,另外由于(yu)天然的(de)材(cai)料,裝修風格上(shang)也(ye)是(shi)特別(bie)的(de)大方(fang),而且經濟實惠對于(yu)很多(duo)人來說都是(shi)比較合適的(de),但是(shi)相對來說使用時間長就會(hui)發生變形的(de)問題(ti)。
2、鋼木材(cai)料:鋼木材(cai)料不會出現變形的(de)(de)問題,而且外觀特別的(de)(de)大氣高雅。但是相對于價格(ge)會貴一點,但是質量特別的(de)(de)好,家(jia)里的(de)(de)裝修(xiu)風格(ge)搭配起來(lai)很豪華。
設計規范
門(men)窗套板(ban)施(shi)工(gong)工(gong)程(cheng)需(xu)在墻面、門(men)窗框安裝等工(gong)程(cheng)施(shi)工(gong)完畢后,再地磚施(shi)工(gong)前進(jin)行,這(zhe)樣,門(men)套骨架才會更穩固牢(lao)靠。
再檢查(cha)基層墻體平整度,誤差超過30mm時,采(cai)用相應措施;墻體破損較(jiao)大時,在木作基層做好后,用水泥砂漿填補平整,才能進行面層施工。
還要檢查(cha)門窗(chuang)框、洞口和安裝部位(wei)抹灰面的(de)平直度,對(dui)于誤差范圍內的(de),及時采(cai)取一定措施糾正;誤差范圍之外的(de),要整改合格才可以繼續(xu)施工。
施工要求標準
首先,檢查基(ji)層材料(liao),選(xuan)用合格(ge)木龍(long)骨及(ji)15mm左右的細木工(gong)板或中纖板為基(ji)層材料(liao)。
其次(ci),依據(ju)設(she)計尺(chi)寸、線型、安裝(zhuang)高(gao)度、壓框高(gao)度、保證(zheng)余量尺(chi)寸一致(zhi),進(jin)行(xing)定位(wei)劃線。同時,要根據(ju)尺(chi)寸做成的(de)骨架找平找直,其后(hou)整(zheng)體或分片安裝(zhuang),并(bing)且找方找直,與基層的(de)空隙應用(yong)木墊釘牢。
再(zai)次,配料加(jia)工制作(zuo)應尺(chi)寸正確,表(biao)面平(ping)直光滑(hua),線角清晰(xi)、棱角方(fang)正、45°割角整齊一致(zhi),無刨(bao)痕、毛刺、錘(chui)印等缺(que)陷(xian)。此外,還要在安裝(zhuang)(zhuang)前對配料進行實地預裝(zhuang)(zhuang),精細修整,使(shi)尺(chi)寸一致(zhi),拼縫平(ping)直嚴密,線角順直,拼接無誤(wu)后再(zai)固定。
最后(hou),安(an)裝固定是(shi)應保證位置正(zheng)確,牢固不松動,釘的間距視材質、截(jie)面尺寸而定,一般不宜大于300mm。安(an)裝時特別注意(yi)同一門(men)窗套所用(yong)的面板要求顏色(se)相(xiang)似(si),無明(ming)顯(xian)色(se)差、紋理順(shun)直、花紋近似(si)。安(an)裝后(hou)接口應嚴正(zheng)平之(zhi)無明(ming)顯(xian)誤(wu)差。
驗收標準
1、檢查門窗的平(ping)整度、垂(chui)直度,允許誤(wu)(wu)差(cha)≤1mm,對角(jiao)線允許誤(wu)(wu)差(cha)≤2mm,檢測門窗上方左右角(jiao)到水平(ping)線距(ju)離,所有門應做到高度一致。
2、基層、面(mian)板底面(mian)膠(jiao)合面(mian)刨(bao)光(guang)后(hou)應(ying)平行,凹(ao)凸(tu)處的(de)允許偏差不應(ying)大(da)于0.5mm,涂膠(jiao)前應(ying)清除(chu)合面(mian)上的(de)油脂,污垢及塵土(tu),膠(jiao)合時必須(xu)加壓,膠(jiao)縫的(de)厚(hou)度(du)一般不得大(da)于0.3mm,不允許有脫膠(jiao)、漏膠(jiao)現象。門(men)窗套面(mian)層膠(jiao)合完畢,
3、細木工板(ban)套(tao)材(cai)下(xia)料基層用(yong)干燥木料打木楔(xie)固定穩固,離地(di)5mm防止(zhi)水浸。封面(mian)層板(ban)使(shi)用(yong)釘子(zi)固定白(bai)乳膠,白(bai)乳膠應涂刷均勻足(zu)量,修邊時(shi)嚴禁(jin)修傷面(mian)板(ban)。
4、門扇制作厚度一般為38mm左右,白乳膠裝鎖處(chu)特別加(jia)固木工板,可(ke)做交叉(cha)開(kai)口(kou)處(chu)理以防變形。
5、門窗如果是(shi)設計磨(mo)(mo)(mo)砂(sha)(sha)玻璃(li)時,裝(zhuang)好后(hou)應(ying)(ying)(ying)在光面部分(fen)打適量玻璃(li)膠,保(bao)護玻璃(li)。廚衛(wei)間磨(mo)(mo)(mo)砂(sha)(sha)面應(ying)(ying)(ying)向(xiang)外,室(shi)外交結處磨(mo)(mo)(mo)砂(sha)(sha)面應(ying)(ying)(ying)向(xiang)內。
6、安(an)裝(zhuang)(zhuang)合頁(ye)須在門(men)窗及門(men)框上雙面開槽門(men)上開口與(yu)合頁(ye)嚴密。門(men)扇裝(zhuang)(zhuang)好后(hou),不(bu)得(de)高于(yu)邊線厚度。安(an)裝(zhuang)(zhuang)后(hou)應開關靈活。
質量隱患
劣質(zhi)吊(diao)頂(ding)的(de)危(wei)害非(fei)常多,如果使用的(de)是回收料(liao)生產(chan)的(de)吊(diao)頂(ding),非(fei)常容(rong)易揮(hui)發(fa)甲(jia)醛等(deng)有(you)害物質(zhi),白血病(bing)就與甲(jia)醛有(you)密切的(de)關系。另外劣質(zhi)吊(diao)頂(ding)還(huan)存(cun)在各種(zhong)指數不達標的(de)問題,時(shi)間長了(le)會(hui)出現褪(tun)色,發(fa)黃,甚(shen)至是斷裂(lie)開縫等(deng)問題,這些都會(hui)影(ying)響人的(de)生命安全(quan)。
質量選材
吊頂的(de)材料有(you)石膏板(ban)、礦棉(mian)板(ban)、PVC板(ban)、鋁扣板(ban)、鋁合金、板(ban)集成吊板(ban)。具體(ti)選(xuan)擇什么吊頂,可根(gen)據消費者(zhe)的(de)具體(ti)需求而(er)定。
設計規范
1、用來(lai)遮擋結構(gou)(gou)構(gou)(gou)件及各種(zhong)設備管道(dao)和裝(zhuang)置(zhi)。
2、對(dui)于有聲學要(yao)求的(de)房(fang)間頂棚(peng),其表面形狀和材料應根據音(yin)質(zhi)要(yao)求來(lai)考慮。
3、吊(diao)頂是室內裝修的重要部(bu)位,應結合(he)室內設(she)(she)計進行統籌考慮,裝設(she)(she)在(zai)頂棚(peng)上的各種燈具(ju)和(he)空(kong)調風口應成為(wei)吊(diao)頂裝修的有機整體。
4、要便于維(wei)修(xiu)隱藏在(zai)吊(diao)頂內的各種裝置和(he)管線。
5、吊頂(ding)應便于工(gong)業化施(shi)工(gong),并盡(jin)量(liang)避免濕作業。
施工要求標準
1、吊(diao)桿(gan)(gan)、龍(long)骨的(de)安裝間距、連接方(fang)式(shi)應(ying)符合設計要求(qiu)。后置埋件、金屬吊(diao)桿(gan)(gan)、龍(long)骨應(ying)進行防(fang)(fang)腐(fu)處理(li)。木(mu)吊(diao)桿(gan)(gan)、木(mu)龍(long)骨、造型木(mu)板和木(mu)飾面板應(ying)進行防(fang)(fang)腐(fu)、防(fang)(fang)火、防(fang)(fang)蛀處理(li)。
2、吊頂材料在(zai)運輸、搬運、安裝、存放時應(ying)采取相應(ying)措施,防(fang)止受潮、變形及損壞板材的表面和(he)邊角。
3、重型(xing)燈具、電扇(shan)及其他重型(xing)設備嚴禁安裝(zhuang)在吊頂龍骨上。
4、吊頂內填充的(de)吸音、保溫材料的(de)品種和鋪(pu)設厚(hou)度應(ying)符合(he)設計要(yao)求(qiu),并應(ying)有防(fang)散落措施(shi)。
5、飾面(mian)板上的燈具(ju)、煙(yan)感器、噴淋頭、風口(kou)蓖子等設備的位置應合理(li)、美觀,與飾面(mian)板交接處(chu)應嚴密。
6、吊頂與墻(qiang)面(mian)、窗簾盒的交(jiao)接應符合設計要求(qiu)。
驗收標準
1、吊頂工程所用材料的品種、規格、顏色以及(ji)基層(ceng)構造、固定(ding)方法應符合設計要求。
2、各類龍骨吊頂必須固定牢固,固定完畢后,要進行一次(ci)全面檢查和校(xiao)平,并檢查安裝位置是否(fou)正確(que)。
3、木(mu)骨架所用(yong)木(mu)方規格應(ying)按設(she)計要求(qiu),各木(mu)方之(zhi)間(jian)應(ying)打膠(jiao)再用(yong)釘固定,與罩面板接(jie)觸的一面必須刨平。
4、頂棚木骨架結(jie)構應(ying)符合防火要求(qiu)。
驗收注意
1、吊(diao)頂平穩是好,但也并非越平整(zheng)越好,需要考(kao)慮到吊(diao)頂龍骨日后下垂的問題,所以檢查時,一般吊(diao)頂龍骨的中心應從(cong)短(duan)邊起拱1/200,才符合(he)標(biao)準。
2、一般需要檢查(cha)吊(diao)頂的表面清潔度,吊(diao)頂空(kong)隙位置(zhi)是否有(you)雜物,或者是否有(you)施工留(liu)下的廢料(liao)等。
3、安(an)裝的吊頂表(biao)面無凹凸不(bu)平,比較光(guang)滑(hua)(hua)即可(ke),并不(bu)需(xu)要過于光(guang)滑(hua)(hua)。過于光(guang)滑(hua)(hua)的表(biao)面反而導致空間反光(guang)度(du)增(zeng)加,易造成家居光(guang)污(wu)染。
質量隱患
未(wei)對(dui)整體網(wang)絡(luo)進行(xing)(xing)前瞻(zhan)性規(gui)劃、語音和數據業務使用不同線(xian)(xian)路(lu)(lu)、沒有對(dui)線(xian)(xian)路(lu)(lu)進行(xing)(xing)有效管理(li)、網(wang)線(xian)(xian)與電纜形成平行(xing)(xing)布設、網(wang)線(xian)(xian)與"干擾"設備在同一區域、不考(kao)慮實際距離的(de)限制、違背法律法規(gui)的(de)要求、忽(hu)視對(dui)線(xian)(xian)路(lu)(lu)進行(xing)(xing)測試(shi)、不遵循行(xing)(xing)業標(biao)準、對(dui)新(xin)增(zeng)線(xian)(xian)路(lu)(lu)未(wei)進行(xing)(xing)合理(li)規(gui)劃。
質量選材
1、線纜(lan)的(de)選擇(ze)應根據系統的(de)要求、技術性(xing)能、投資概算(suan)等綜(zong)合地進行考慮。
2、屏蔽與非(fei)屏蔽線纜的(de)(de)選擇,取決于外部電磁干擾的(de)(de)情況
3、要結合布線(xian)系(xi)統的應(ying)用需(xu)求來考慮線(xian)纜類別的選擇。
4、線系統(tong)要既考慮到目(mu)前的(de)需(xu)求,又要適(shi)當兼顧今后(hou)的(de)發展,也(ye)不能忽視(shi)外部因素。
設計規范
應(ying)遵(zun)循(xun)布(bu)線部件(jian)標(biao)準和設計(ji)標(biao)準,布(bu)線方案設計(ji)應(ying)遵(zun)循(xun)布(bu)線系(xi)統性能、系(xi)統設計(ji)標(biao)準,布(bu)線施工(gong)工(gong)程應(ying)遵(zun)循(xun)布(bu)線測試、安裝、管理(li)標(biao)準及(ji)防(fang)(fang)火、機房及(ji)防(fang)(fang)雷接地標(biao)準。
驗收標準
1、綜合布線系(xi)統工程(cheng)應按照《大(da)樓通(tong)信綜合布線系(xi)統第一部分:總規范》(YD/T926.1—1997)中(zhong)規定的鏈(lian)路性(xing)能要(yao)求進行驗收。
2、工(gong)程(cheng)竣工(gong)驗收項(xiang)目的(de)內容和(he)方法(fa),應按照《建(jian)筑(zhu)和(he)建(jian)筑(zhu)群(qun)綜合布線系統(tong)工(gong)程(cheng)驗收規(gui)范(fan)》(GB/T50312—2000)的(de)規(gui)定執行。
3、綜合(he)布線(xian)(xian)(xian)系(xi)(xi)統線(xian)(xian)(xian)纜鏈(lian)路的電(dian)氣(qi)性(xing)能驗收(shou)測試(shi)(shi),應按照《綜合(he)布線(xian)(xian)(xian)系(xi)(xi)統電(dian)氣(qi)特性(xing)通用測試(shi)(shi)方(fang)法(fa)》(YD/T1013—1999)中的規定辦理。
4、綜(zong)合布線系統工(gong)程的驗(yan)收除(chu)了應(ying)該符(fu)合上述規范(fan)外,還應(ying)該符(fu)合我(wo)國現行(xing)的《本地網通信線路工(gong)程驗(yan)收規范(fan)》(YD5051—1997)和《通信管道工(gong)程施(shi)工(gong)及驗(yan)收技(ji)術規范(fan)》(YDJ39—1997)中(zhong)相關的規定。