一、電源時序器和電源控制器的區別
1、電源時序器
電(dian)(dian)(dian)(dian)源(yuan)時(shi)序(xu)器能(neng)夠按(an)照由前(qian)級設備(bei)(bei)到(dao)后(hou)級設備(bei)(bei)逐個順序(xu)啟動電(dian)(dian)(dian)(dian)源(yuan),關閉供電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)源(yuan)時(shi)則由后(hou)級到(dao)前(qian)級的(de)順序(xu)關閉各類用(yong)(yong)電(dian)(dian)(dian)(dian)設備(bei)(bei),這(zhe)樣(yang)就能(neng)有(you)效的(de)統一管理和(he)控制各類用(yong)(yong)電(dian)(dian)(dian)(dian)設備(bei)(bei),避(bi)免了(le)人為的(de)失誤(wu)操作(zuo),同時(shi)又可減低用(yong)(yong)電(dian)(dian)(dian)(dian)設備(bei)(bei)在開關瞬(shun)間對供電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)網的(de)沖(chong)擊,也避(bi)免了(le)電(dian)(dian)(dian)(dian)流(liu)對設備(bei)(bei)的(de)沖(chong)擊,確保了(le)整個用(yong)(yong)電(dian)(dian)(dian)(dian)系統的(de)穩定。(自(zi)身對外接設備(bei)(bei)進行智能(neng)控制)
2、電源控制器
電(dian)(dian)源控(kong)制器(qi),可(ke)以發送RS-232和RS-485代碼,用(yong)電(dian)(dian)腦和中控(kong)對設備(bei)進行控(kong)制,如(ru)設備(bei)開關(guan),投影機(ji)延時關(guan)機(ji),電(dian)(dian)動屏幕(mu)、電(dian)(dian)動窗(chuang)簾、電(dian)(dian)動吊架的升降控(kong)制等(deng)。(可(ke)以通過協(xie)議連接外部控(kong)制設備(bei)對負載進行控(kong)制)
二、如何挑選電源時序器
1、穩壓性
時(shi)序器穩(wen)定運行的(de)是系(xi)統可(ke)靠的(de)前提,時(shi)序器經常不(bu)開(kai)機(ji),或時(shi)不(bu)時(shi)有(you)一兩個通道不(bu)開(kai),這樣再好系(xi)統都白搭(da)。除本身運行可(ke)靠外,還需(xu)要有(you)一定的(de)抗干(gan)擾(rao)能(neng)力,對(dui)時(shi)序沖(chong)擊的(de)干(gan)擾(rao)源一部(bu)分(fen)(fen)來電(dian)源外網,這部(bu)分(fen)(fen)干(gan)擾(rao)主要有(you)感應雷、電(dian)動(dong)機(ji)、日光燈(deng)等(deng)產(chan)生的(de)浪涌和脈沖(chong)尖峰;另一部(bu)分(fen)(fen)是系(xi)統起動(dong)時(shi),設備內部(bu)電(dian)源充(chong)電(dian)或開(kai)關電(dian)源造成的(de)干(gan)擾(rao)。
2、測試時序器穩定性
首(shou)先給時(shi)(shi)序(xu)(xu)器(qi)(qi)上電(dian),將時(shi)(shi)序(xu)(xu)器(qi)(qi)時(shi)(shi)序(xu)(xu)間隔時(shi)(shi)間設(she)為1秒,然(ran)后(hou)起動時(shi)(shi)序(xu)(xu)啟(qi)動功能,在起動過程(cheng)中(zhong)開關(guan)房(fang)間內的(de)日(ri)光燈或電(dian)鉆(zhan)等,注(zhu)(zhu)意(yi)時(shi)(shi)序(xu)(xu)器(qi)(qi)不能有重啟(qi)或有通(tong)道不開的(de)情況,這種方法要(yao)(yao)測(ce)試(shi)多次。如果有條(tiao)件的(de)可能用脈沖發生器(qi)(qi)向時(shi)(shi)序(xu)(xu)器(qi)(qi)供電(dian)市電(dian)(220V電(dian))注(zhu)(zhu)入干擾脈沖,測(ce)試(shi)中(zhong)分(fen)次增(zeng)加干擾強(qiang)度(du),以測(ce)試(shi)出被測(ce)時(shi)(shi)序(xu)(xu)器(qi)(qi)的(de)抗干擾強(qiang)度(du),一般來說要(yao)(yao)達到1KV(1000V)以上。
給時(shi)序(xu)器的每個輸(shu)出都(dou)接上負(fu)載(zai)(zai)(最好是大(da)功(gong)(gong)率功(gong)(gong)放),如(ru)沒有那么多負(fu)載(zai)(zai),可以將負(fu)載(zai)(zai)接到(dao)連續的后(hou)幾路上(如(ru)CH12、11、10、9)。然后(hou)給時(shi)序(xu)器上電并起(qi)動時(shi)序(xu)起(qi)動功(gong)(gong)能(neng)(注意如(ru)時(shi)序(xu)間(jian)(jian)隔時(shi)間(jian)(jian)可調的設備,要將間(jian)(jian)隔時(shi)間(jian)(jian)調整到(dao)1秒),起(qi)動過程看時(shi)序(xu)器不能(neng)有重(zhong)啟或有通(tong)道不開的情況。
3、容量
系統整體的(de)(de)(de)電(dian)流(liu)需求是挑(tiao)選(xuan)(xuan)時(shi)(shi)(shi)序器(qi)容量的(de)(de)(de)標(biao)準,現市場(chang)有(you)20A、30A、40A、50A電(dian)流(liu)的(de)(de)(de)可供挑(tiao)選(xuan)(xuan);單(dan)路的(de)(de)(de)容量一(yi)般為10A或13A;現在有(you)的(de)(de)(de)廠家吹(chui)自(zi)己(ji)使(shi)用(yong)30A的(de)(de)(de)繼電(dian)器(qi),輸出(chu)電(dian)流(liu)達(da)30A,而輸出(chu)座卻使(shi)用(yong)的(de)(de)(de)是美式或萬能(neng)(neng)式插(cha)座,這種座的(de)(de)(de)額定電(dian)流(liu)是10A,有(you)的(de)(de)(de)加厚彈片的(de)(de)(de)是13A。由此(ci)看出(chu)輸出(chu)電(dian)流(liu)是達(da)不(bu)來到30A的(de)(de)(de),大(da)伙可以用(yong)30A的(de)(de)(de)負載測試一(yi)下(xia);測試時(shi)(shi)(shi)用(yong)電(dian)流(liu)達(da)10A的(de)(de)(de)負載,接到標(biao)稱(cheng)總容量電(dian)流(liu),煮(zhu)水4小時(shi)(shi)(shi)。電(dian)源(yuan)引線表面(mian)溫度不(bu)能(neng)(neng)超60度,摸起來不(bu)燙手;時(shi)(shi)(shi)序器(qi)不(bu)能(neng)(neng)發出(chu)糊味(wei)。
4、可擴展
電源(yuan)時序(xu)器輸(shu)出通道數(shu)分為4路(lu)、8路(lu)、10路(lu)、12路(lu)等、當設備(bei)的數(shu)量超過(guo)一(yi)(yi)(yi)臺時序(xu)器通道的數(shu)量時,就要(yao)擴展(zhan)(級聯)使用了,選(xuan)擇時要(yao)注(zhu)意擴展(zhan)后能從第一(yi)(yi)(yi)路(lu)開到最后一(yi)(yi)(yi)路(lu),還能從最后一(yi)(yi)(yi)路(lu)關到第一(yi)(yi)(yi)路(lu)。
5、功能
按項目要求挑選,如(ru)電平起(qi)動功(gong)能,RS232、RS485、TCP/IP控制(zhi)功(gong)能,狀態(tai)監控;時序間隔、常開配置功(gong)能;電源凈化、防浪(lang)涌(yong)、電壓、電流監測保(bao)護(hu)功(gong)能等。